电力电子电容器
想要找到您需要的电容器,您可以在我们的数据库中按现有的产品查找,也可以将您需要的参数通过询价表发给我们,或者按传统的办法,翻阅这里的样本。样本按产品家族分类,可提供关于产品的所有信息和可能性。条条大路通罗马。
DC Capacitors
E67, PK16, E80, E61
- cylindrical shape, dry design (no liquids), very low self-inductance
- DC voltage range: 500V...4000V
- Capacitance: 100...7400µF
- RMS current rating up to 120A
Publication No.: 200.003-020030
Edition: 10/2024
Language: English/GermanChangelog
E57/E59/SR17
Box-shaped capacitors for heavy currents and large capacitances
- Steel, aluminum or plastic housing
- dry design (no liquids)
- reliable protection by pressure switch
- DC voltage range: 500 ... 25,000 V
- AC voltage range: 200 ... 17,000 V
Publication No.: 200.003-020070
Edition: 12/2022
Language: English/German
E62 and E64
AC capacitors for universal use with BAM protection
metal can, cylindrical shape, oil-filled, internal safety mechanism- AC voltage range: 420Vac (300Vrms) ... 5000Vac (3500Vrms)
- DC voltage range: 700V...5000V
Publication No.: 200.003-020060
Edition: 08/2024
Language: English/GermanChangelog
E62-3ph and 3HF
Three phase Heavy Duty capacitors for filters and PFC
- 640Vac (450Vrms) ... 1700Vac (1200Vrms)
- oil filled
Publication No.: 200.003-020051
Edition: 11/2024
Language: English/GermanChangelog
E51/E53/E55
low-inductance AC/DC capacitors for general use, especially for high operating voltages
- plastic can, cylindrical shape, dry design (no liquids)
- very low self-inductance
- DC voltage range: 600V ... 50,000 V
- AC voltage range: 280V ... 20,000 V
Publication No.: 200.003-020080
Edition: 08/2024
Language: English/GermanChangelog
E63
DC capacitors for universal use with BAM protection
- metal can, cylindrical shape, oil-filled, internal safety mechanism
- DC voltage range: 700 V ... 5000 V
- Ripple-Voltage ratings: 200 V ... 700 V
Publication No.: 200.003-020020
Edition: 05/2023
Language: English/German
ZVEI Guideline Partial Discharge Measurements
PD measurements on capacitors are intended to detect potential defects in the insulation in order to prevent future failures, as partial discharges may weaken the insulation to the housing and within the dielectric.
The procedures for PD measurements are described in various IEC standards. However, especially with regard to the testing of capacitors, there may be limitations and misinterpretations regarding the informative value of such tests. This common guideline by the capacitor manufacturers organized in the ZVEI intends to prevent such misunderstandings.